Robertshaw Part Number 780U-IP10

Intermittent Pilot Ignition Module

Applications: Gas Furnaces, Boilers, Water Heaters, and Commercial Cooking

Features:

  • Configurable 24V ignition module
  • Selectable number of trials, pre-purge, trial for ignition, inter-purge and restart time
  • Replaces over 150 models including Honeywell, White-Rodgers, Johnson Controls and others
  • Flame sensing supports both single rod (local sense) and two rod (remote sense)
  • Compatible with both Natural and LP gas
  • Vent damper connection allows for connection to a vent damper
  • LED indicator provide troubleshooting and notifications for flame presence/strength and displays systems status and errors

Applications:

  • Gas Furnaces
  • Boilers
  • Water Heaters
  • Commercial Cooking

Specifications:

  • Input Power: 24VAC ± 4VAC 50-60 Hz
  • Input Current: Max 0.25 A + Valve at 2A Max
  • High Voltage Output: 15 KV with 50 pf load
  • Spark Gap: 0.150 in ± 0.050 in (3.8 mm ± 1.2 mm)
  • Flame Sensor Current: 0.5 Microamperes (uA) minimum
  • Flame Failure Re-Ignition Time: Maximum 1 second
  • Vent Damper: Optional, use Molex 03-06-2061
  • Ambient Temperature: -40 °F to + 176 °F (-40 °C to +80 °C)
  • Humidity Range: Up to 95% relative humidity non-condensing

Replacement for manufacturer series numbers Baso: C610U, ICM: ICM2918, Resideo/Honeywell: S8610U3009/U, White-Rodgers: 50D50-801, Fenwal: 35-63, Johnson Controls: G60/65/67/77